The ENV200C clamp-on density measurement guarantees fit-and-forget and reliable measurement with almost no influence on measuring medium. Different from other density meters, its measurement isn't affected by pressure, corrosiveness, nor abrasiveness. As the clamp-on sensor can be mounted outside of pipe line even under flow-running condition, the user neither need to stop their process nor to consider the corrosiveness of liquid.
- Continuous Measurement
- No Maintenance
- No Space and Tool
- No Additional Cost
- No Limit on Measuring ASF (Automatic Signal Filter)
Clamp-On Ultrasonic Sludge Density Meter - ENV200C
Controller – C2S2
- Measuring Principle : Ultrasonic Attenuation and EEAM(Envelope Energy Average Method)
- Measuring Range : 1,000~1,500kg/m³(1.000~1.500g/cm³)
- Measuring Mode : Process Mode, Real‐time
- Mode Display : Graphic LCD (Density, Time, Echo profile, mA, Etc.)
- Accuracy : +/‐ 1% of F.S.
- Repeatability: +/‐1% of reading
- Operating Temp : ‐20 ~ +70°C
- Outputs : Current : 4~20mA, nom. Load 250Ω (load range : 100 ~ 750Ω) Relay : 3 SPDT(5A, 250VAC) –“ER” ”R1” “R2”
- Digital: RS232(STD.), RS485(Option)
- Power Supply : STD. 100 ~ 240V AC, 50~60Hz, ≤6W 22 ~ 26VDC
- Enclosure Material : Body/Cover Polycarbonate
- Rating : IP67
- Data Saving : Max. 400 days data logging and trend
- Screen : Numeric, Data trend, Diagnosis, Echo profile
- Certificate : CE
Model- Clamp on S2C
- Material: Body MC Nylon
- Ultrasonic Head: Epoxy
- Pipe Size: 50 to 300
- Operating Temp: -10 to +60 Deg C
- Cable lengh: 10m (Std)
- IP Rating: IP 65