Density and concentration drive many process decisions. Three technologies cover most inline needs.
A tuning fork vibrates at a resonant frequency that changes with the density of the liquid around it. The meter converts the frequency into density, with temperature compensation. It is a direct-insertion device, suited to clean to moderately dirty liquids.
The HYKO® TD-701 measures 500 to 2,500 kg/m³ with pressures up to 207 bar. For full accuracy it needs a full, liquid-filled measurement section.
Ultrasonic meters measure how sound is attenuated as it passes through a liquid or slurry. They suit sludge and solids-bearing fluids where a vibrating element could foul. The ENV200 covers 1,000 to 2,000 kg/m³ with spool-piece, tank-mount and clamp-on sensor options.
A Coriolis meter vibrates a tube and reads its resonant frequency for density, while the twisting of the tube gives mass flow. Temperature is measured too. One meter therefore reports mass flow, density and temperature together. The HYKO® CM-1000 reads density to ±0.002 g/cm³.
In a pyrolysis oil day tank, a tuning fork density meter in the draw-off path sees the density change as water gives way to oil, so the PLC can close the drain valve before oil is lost.
Density is mass per unit volume. For a known mixture, density can be converted into a concentration, such as the percentage of a solid in a slurry.
Yes. Good density meters measure temperature and compensate for it.
Tell us your application and we will recommend an instrument.
Related searches: tuning fork density meter, inline density meter, Coriolis density meter, ultrasonic sludge density meter, density meter for oil water interface.