Clamp-on ultrasonic flow meters measure liquid flow from the outside of the pipe, so the line is never cut and the process keeps running.
Two sensors are mounted on the outside of the pipe. One sends an ultrasonic pulse to the other with the flow, then the roles reverse and a pulse travels against the flow. The pulse travelling with the flow arrives slightly sooner than the one travelling against it.
The meter measures the difference in transit time, which is proportional to the average flow velocity. Multiplying velocity by the cross-section of the pipe gives the volumetric flow.
On smaller pipes the two sensors sit on the same side and the pulse reflects across the pipe. This V-method is recommended up to DN1000. On larger pipes the sensors sit on opposite sides, the Z-method, recommended above DN1000.
A wall-mounted transmitter with fixed sensors suits permanent monitoring and feeds a control system by 4–20 mA or Modbus. A portable meter is handy for flow audits, commissioning checks and verifying an installed meter without stopping the line.
The HYKO® UF-100 series is rated at ±1% of reading with 0.2% repeatability, over a velocity range of 0.1 to 12 m/s, on pipes from DN15 to very large diameters.
No. The sensors sit on the outside of the pipe and nothing enters the liquid.
No. Clamp-on measurement needs a full pipe. For open channels use an open-channel flow meter.
Yes. A portable clamp-on meter can be strapped onto the pipe next to an installed meter to compare readings.