Three technologies cover most level jobs. The right one depends on your product, vessel and conditions.
An ultrasonic transmitter sends a sound pulse down to the surface and times the echo. It is simple and economical for clean liquids in open or vented tanks. Foam, vapour and strong temperature changes can disturb the sound path, and there is a short blind zone close to the sensor.
The HYKO® UL-300 measures from 5 to 30 m with a blind zone of 50 to 300 mm.
Radar uses radio waves, so vapour, pressure and temperature changes have little effect. Lower-frequency 26GHz horn radar suits long ranges and hot vessels, with the HYKO® RL-400 reaching 70 m and 250°C. Higher-frequency 80GHz radar has a narrow beam that copes better with small tanks and nearby obstructions, with ±2 mm accuracy on the RL-400L for liquids and the RL-400S for powders and solids.
Guided wave radar sends the pulse down a probe that touches the product. It works well in narrow or cluttered vessels and where turbulence or foam would confuse a non-contact device, as long as the probe material suits the product. The HYKO® GWR-450 covers 0 to 10 m with ±5 mm accuracy.
Not always. Radar is more tolerant of vapour and temperature, but ultrasonic is often enough and more economical for clean liquids in simple tanks.
Yes. Ultrasonic and radar transmitters are non-contact. Guided wave radar uses a probe in the product.
Tell us your application and we will recommend an instrument.
Related searches: ultrasonic vs radar level transmitter, how to choose a level transmitter, guided wave radar level, 80GHz radar level meter, non-contact level measurement.